| Parameter | Value |
|---|---|
| Orderable part number | HCMA1305-2R2-R |
| OCL (open circuit inductance) | 2.20 uH ±20% |
| FLL minimum, at Isat | 1.41 uH |
| Irms (DC, 40 °C rise) | 20 A |
| Isat (20% rolloff @ +25 °C) | 32 A |
| DCR typical @ +20 °C | 4.6 mOhm |
| DCR maximum @ +20 °C | 5.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 191, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10277 |

Drawing reproduced from Eaton Technical Data 10277: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified high-current inductor on a molded powder core, rated to +125 °C. The construction is chosen for current density: the winding is pressed into the magnetic material, so there is no bobbin wasting window area and the DCR stays low for the body size.
Copper loss at the rated current works out to roughly 1.84 W from a typical DCR of 4.6 mOhm at 20 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Stored energy at Isat is about 1,126 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
With K = 191, a peak-to-peak ripple of one amp produces roughly 420 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Of the 21 values listed for HCMA1305, this is the 11th, in a family covering 0.1 uH to 33 uH.
Compared with its neighbours in the table, HCMA1305-3R3-R trades 6 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 5.29 mOhm becomes roughly 7.47 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
Can it be used on a 48 V rail?
The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.
How does this differ from the commercial HCM part?
Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd