| Parameter | Value |
|---|---|
| Orderable part number | HCMA1305-8R2-R |
| OCL (open circuit inductance) | 8.20 uH ±20% |
| FLL minimum, at Isat | 5.25 uH |
| Irms (DC, 40 °C rise) | 9.5 A |
| Isat (20% rolloff @ +25 °C) | 18 A |
| DCR typical @ +20 °C | 17.5 mOhm |
| DCR maximum @ +20 °C | 20.1 mOhm |
| K-factor (Bp-p = K x L x dI) | 117, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10277 |

Drawing reproduced from Eaton Technical Data 10277: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.
At the rated 9.5 A the winding dissipates about 1.58 W in copper alone, using the typical DCR of 17.5 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 1,328 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 117 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 959 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Of the 21 values listed for HCMA1305, this is the 17th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCMA1305-100-R, gives 10.0 uH at 9 A and DCR 19 mOhm: the extra inductance costs about 1 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 20.1 mOhm becomes roughly 28.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd