Eaton HCMA1707-220-R AEC-Q200 Inductor 22 uH, Isat 11 A
Eaton HCMA1707-220-R AEC-Q200 Inductor 22 uH, Isat 11 A

Eaton HCMA1707-220-R AEC-Q200 Inductor 22 uH, Isat 11 A

Share
Eaton HCMA1707-220-R: AEC-Q200 high-current inductor, 22 uH ±20%, 9.5 A Irms, Isat 11 A, DCR 21 mOhm, 17.5 x 17.2 mm.
    • Product Details
    • Download

    Eaton HCMA1707-220-R AEC-Q200 Inductor 22 uH, Isat 11 A

    HCMA1707-220-R at a glance: AEC-Q200 high-current inductor, 22 uH ±20%, 9.5 A Irms, Isat 11 A (20% rolloff @ +25 °C), DCR 21 mOhm, 17.5 x 17.2 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCMA1707-220-R
    OCL (open circuit inductance)22 uH ±20%
    FLL minimum, at Isat14.1 uH
    Irms (DC, 40 °C rise)9.5 A
    Isat (20% rolloff @ +25 °C)11 A
    DCR typical @ +20 °C21 mOhm
    DCR maximum @ +20 °C23 mOhm
    K-factor (Bp-p = K x L x dI)37, Bp-p in Gauss
    Package17.5 x 17.2 mm
    Height7.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10296

    Outline Drawing

    HCMA1707-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10296: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.

    At the rated 9.5 A the winding dissipates about 1.9 W in copper alone, using the typical DCR of 21 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Energy storage at the saturation current is around 1,331 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 37 means the flux swing is about 814 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Where This Series Fits

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    In the HCMA1707 line-up this part is number 8 of 11 by inductance, between 1.5 uH and 68 uH.

    One step down the table, HCMA1707-150-R, sits at 15 uH with 12 A and 14.5 mOhm – the lower inductance buys about 3 A of extra current in the same body.

    • Core material: iron powder core, 17.5 x 17.2 mm body at 7.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 23 mOhm becomes roughly 32.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Confirm the terminal spacing against the rail voltage.
    • Check the terminal spacing against the rail voltage and the coating scheme.
    • Verify the shielding against the EMC plan for the board.

    Frequently Asked Questions

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Is it shielded?
    Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Shenzhen Gaorunxin Technology Co., Ltd