| Parameter | Value |
|---|---|
| Orderable part number | HCMA1707-8R2-R |
| OCL (open circuit inductance) | 8.2 uH ±20% |
| FLL minimum, at Isat | 5.25 uH |
| Irms (DC, 40 °C rise) | 16 A |
| Isat (20% rolloff @ +25 °C) | 20 A |
| DCR typical @ +20 °C | 8.1 mOhm |
| DCR maximum @ +20 °C | 8.7 mOhm |
| K-factor (Bp-p = K x L x dI) | 55, Bp-p in Gauss |
| Package | 17.5 x 17.2 mm |
| Height | 7.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10296 |

Drawing reproduced from Eaton Technical Data 10296: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.
Copper loss at the rated current works out to roughly 2.07 W from a typical DCR of 8.1 mOhm at 16 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
At Isat the part holds about 1,640 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 55 means the flux swing is about 451 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Within the HCMA1707 family this is value 5 of 11, in a range that runs from 1.5 uH to 68 uH.
Compared with its neighbours in the table, HCMA1707-100-R trades 6 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 8.7 mOhm becomes roughly 12.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd