Eaton HCP0704-1R0-R 1.00 uH Shielded Power Inductor
Eaton HCP0704-1R0-R 1.00 uH Shielded Power Inductor

Eaton HCP0704-1R0-R 1.00 uH Shielded Power Inductor

Share
Eaton HCP0704-1R0-R: iron powder high-current inductor, 1.00 uH ±25%, 12 A Irms, Isat 17 A, DCR 6.2 mOhm, 6.8 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCP0704-1R0-R 1.00 uH Shielded Power Inductor

    HCP0704-1R0-R at a glance: iron powder high-current inductor, 1.00 uH ±25%, 12 A Irms, Isat 17 A (20% rolloff @ +25 °C), DCR 6.2 mOhm, 6.8 x 6.8 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCP0704-1R0-R
    OCL (open circuit inductance)1.00 uH ±25%
    FLL minimum, at Isat0.7 uH
    Irms (DC, 40 °C rise)12 A
    Isat (20% rolloff @ +25 °C)17 A
    DCR typical @ +20 °C6.2 mOhm
    K-factor (Bp-p = K x L x dI)265, Bp-p in Gauss
    Package6.8 x 6.8 mm
    Height4.2 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4348

    Mechanical Dimensions & Pad Layout

    HCP0704-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4348: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    The core here is iron powder, pressed into a shielded body. Iron powder has lower permeability than ferrite but far higher saturation flux density, which is why this family is used where the DC bias is large and the inductance value is modest.

    Copper loss at the rated current works out to roughly 0.893 W from a typical DCR of 6.2 mOhm at 12 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 144 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The K-factor of 265 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 265 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    What This Family Is For

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    Within the HCP0704 family this is value 3 of 7, in a range that runs from 0.4 uH to 4.7 uH.

    The next value up in the same family, HCP0704-1R8-R, gives 1.80 uH at 8.5 A and DCR 11 mOhm: the extra inductance costs about 5.5 A of rated current.

    • Core material: iron powder core, 6.8 x 6.8 mm body at 4.2 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; desktop and servers; base station equipment; notebook and laptop regulators; data networking and storage systems.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 6.2 mOhm becomes roughly 9.49 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Read the inductance at the actual DC bias from the curve before sizing ripple.
    • Read the inductance at the actual DC bias from the curve before sizing ripple.
    • Check the K-factor against the ripple amplitude to estimate core loss.

    Frequently Asked Questions

    Is the part suitable for a high-frequency design?
    Iron powder suits the low-to-mid hundreds of kilohertz range. Above that the loss of the powder material rises faster than ferrite, so compare the loss curves before choosing.

    Why iron powder rather than ferrite?
    Iron powder saturates at a much higher flux density, so a small core can carry a large DC bias. The price is lower permeability, which means more turns and higher DCR for the same inductance.

    Why iron powder rather than ferrite?
    Iron powder saturates at a much higher flux density, so a small core can carry a large DC bias. The price is lower permeability, which means more turns and higher DCR for the same inductance.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products