Eaton HCP0704-4R7-R 4.70 uH Shielded Power Inductor
Eaton HCP0704-4R7-R 4.70 uH Shielded Power Inductor

Eaton HCP0704-4R7-R 4.70 uH Shielded Power Inductor

Share
Eaton HCP0704-4R7-R: iron powder high-current inductor, 4.70 uH ±25%, 5 A Irms, Isat 8 A, DCR 29.5 mOhm, 6.8 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCP0704-4R7-R 4.70 uH Shielded Power Inductor

    HCP0704-4R7-R at a glance: iron powder high-current inductor, 4.70 uH ±25%, 5 A Irms, Isat 8 A (20% rolloff @ +25 °C), DCR 29.5 mOhm, 6.8 x 6.8 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCP0704-4R7-R
    OCL (open circuit inductance)4.70 uH ±25%
    FLL minimum, at Isat3.29 uH
    Irms (DC, 40 °C rise)5 A
    Isat (20% rolloff @ +25 °C)8 A
    DCR typical @ +20 °C29.5 mOhm
    K-factor (Bp-p = K x L x dI)128, Bp-p in Gauss
    Package6.8 x 6.8 mm
    Height4.2 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4348

    Dimensions and Pad Layout

    HCP0704-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4348: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    This part trades inductance per unit volume for current handling: iron powder saturates at a much higher flux density than ferrite, and the soft curve means the converter still has inductance at peak current. Standard choice for multiphase buck stages and battery power systems.

    At the rated 5 A the winding dissipates about 0.738 W in copper alone, using the typical DCR of 29.5 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 150 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 128, a peak-to-peak ripple of one amp produces roughly 600 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    In the HCP0704 line-up this part is number 7 of 7 by inductance, between 0.4 uH and 4.7 uH.

    The next value up in the same family, HCP0704-3R3-R, gives 3.30 uH at 6 A and DCR 25 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: iron powder core, 6.8 x 6.8 mm body at 4.2 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; desktop and servers; base station equipment; notebook and laptop regulators; data networking and storage systems.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 29.5 mOhm becomes roughly 45.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Check the inductance at the operating bias, not the catalogue value.
    • Check the inductance at the operating bias, not the catalogue value.
    • Check the inductance at the operating bias, not the catalogue value.

    Frequently Asked Questions

    Is the part suitable for a high-frequency design?
    Iron powder suits the low-to-mid hundreds of kilohertz range. Above that the loss of the powder material rises faster than ferrite, so compare the loss curves before choosing.

    What core loss should I expect?
    Read the core-loss curve at the flux amplitude implied by the K-factor and the ripple, at the switching frequency. Core loss is quoted per unit volume, so compare curves rather than single numbers.

    Is it shielded?
    The powder core encloses the winding, so the fringing field is limited. It is suitable for multiphase layouts where inductors sit side by side.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products