| Parameter | Value |
|---|---|
| Orderable part number | HCP0704-4R7-R |
| OCL (open circuit inductance) | 4.70 uH ±25% |
| FLL minimum, at Isat | 3.29 uH |
| Irms (DC, 40 °C rise) | 5 A |
| Isat (20% rolloff @ +25 °C) | 8 A |
| DCR typical @ +20 °C | 29.5 mOhm |
| K-factor (Bp-p = K x L x dI) | 128, Bp-p in Gauss |
| Package | 6.8 x 6.8 mm |
| Height | 4.2 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4348 |

Drawing reproduced from Eaton Technical Data 4348: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This part trades inductance per unit volume for current handling: iron powder saturates at a much higher flux density than ferrite, and the soft curve means the converter still has inductance at peak current. Standard choice for multiphase buck stages and battery power systems.
At the rated 5 A the winding dissipates about 0.738 W in copper alone, using the typical DCR of 29.5 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 150 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 128, a peak-to-peak ripple of one amp produces roughly 600 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.
In the HCP0704 line-up this part is number 7 of 7 by inductance, between 0.4 uH and 4.7 uH.
The next value up in the same family, HCP0704-3R3-R, gives 3.30 uH at 6 A and DCR 25 mOhm: the extra inductance costs about 0 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 29.5 mOhm becomes roughly 45.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.
Is the part suitable for a high-frequency design?
Iron powder suits the low-to-mid hundreds of kilohertz range. Above that the loss of the powder material rises faster than ferrite, so compare the loss curves before choosing.
What core loss should I expect?
Read the core-loss curve at the flux amplitude implied by the K-factor and the ripple, at the switching frequency. Core loss is quoted per unit volume, so compare curves rather than single numbers.
Is it shielded?
The powder core encloses the winding, so the fringing field is limited. It is suitable for multiphase layouts where inductors sit side by side.