Eaton HCP0805-1R0-R: iron powder high-current inductor, 1.0 uH ±20%, 14.5 A Irms, Isat 22 A, DCR 5.8 mOhm, 7.9 x 7.6 mm.
    • Product Details
    • Download

    Eaton HCP0805-1R0-R 1.0 uH Iron Powder Inductor, 14.5 A

    HCP0805-1R0-R at a glance: iron powder high-current inductor, 1.0 uH ±20%, 14.5 A Irms, Isat 22 A (20% rolloff @ +25 °C), DCR 5.8 mOhm, 7.9 x 7.6 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCP0805-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.64 uH
    Irms (DC, 40 °C rise)14.5 A
    Isat (20% rolloff @ +25 °C)22 A
    DCR typical @ +20 °C5.8 mOhm
    K-factor (Bp-p = K x L x dI)239, Bp-p in Gauss
    Package7.9 x 7.6 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4349

    Dimensions and Pad Layout

    HCP0805-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4349: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    A shielded iron powder inductor for high-current switching stages. The distributed gap of the powder core spreads the stored energy through the volume, so the part handles a large DC component without local saturation, and the shielding keeps the fringing field small.

    Copper loss at the rated current works out to roughly 1.22 W from a typical DCR of 5.8 mOhm at 14.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 242 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 239 means the flux swing is about 239 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    What This Family Is For

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    The HCP0805 family spans 0.4 uH to 2.2 uH; this row sits at position 3 of 5.

    One step down the table, HCP0805-R68-R, sits at 0.68 uH with 17.5 A and 4.5 mOhm – the lower inductance buys about 4.2 A of extra current in the same body.

    • Core material: iron powder core, 7.9 x 7.6 mm body at 5.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 5.8 mOhm becomes roughly 8.19 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Confirm the K-factor against the ripple amplitude for the core-loss estimate.
    • Check the K-factor against the ripple amplitude to estimate core loss.
    • Verify the footprint against the recommended pad layout.

    Frequently Asked Questions

    What does the K-factor tell me?
    It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.

    Why iron powder rather than ferrite?
    Iron powder saturates at a much higher flux density, so a small core can carry a large DC bias. The price is lower permeability, which means more turns and higher DCR for the same inductance.

    Is the part suitable for a high-frequency design?
    Iron powder suits the low-to-mid hundreds of kilohertz range. Above that the loss of the powder material rises faster than ferrite, so compare the loss curves before choosing.