Eaton HCP0805-1R5-R 1.5 uH Shielded Power Inductor
Eaton HCP0805-1R5-R 1.5 uH Shielded Power Inductor

Eaton HCP0805-1R5-R 1.5 uH Shielded Power Inductor

Share
Eaton HCP0805-1R5-R: iron powder high-current inductor, 1.5 uH ±20%, 13.3 A Irms, Isat 18 A, DCR 6.8 mOhm, 7.9 x 7.6 mm.
    • Product Details
    • Download

    Eaton HCP0805-1R5-R 1.5 uH Shielded Power Inductor

    HCP0805-1R5-R at a glance: iron powder high-current inductor, 1.5 uH ±20%, 13.3 A Irms, Isat 18 A (20% rolloff @ +25 °C), DCR 6.8 mOhm, 7.9 x 7.6 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCP0805-1R5-R
    OCL (open circuit inductance)1.5 uH ±20%
    FLL minimum, at Isat0.96 uH
    Irms (DC, 40 °C rise)13.3 A
    Isat (20% rolloff @ +25 °C)18 A
    DCR typical @ +20 °C6.8 mOhm
    K-factor (Bp-p = K x L x dI)202, Bp-p in Gauss
    Package7.9 x 7.6 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4349

    Outline Drawing

    HCP0805-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4349: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This part trades inductance per unit volume for current handling: iron powder saturates at a much higher flux density than ferrite, and the soft curve means the converter still has inductance at peak current. Standard choice for multiphase buck stages and battery power systems.

    Copper loss at the rated current works out to roughly 1.2 W from a typical DCR of 6.8 mOhm at 13.3 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 243 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 202 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 303 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Where This Series Fits

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    Within the HCP0805 family this is value 4 of 5, in a range that runs from 0.4 uH to 2.2 uH.

    Compared with its neighbours in the table, HCP0805-2R2-R trades 4.5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 7.9 x 7.6 mm body at 5.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 6.8 mOhm becomes roughly 9.61 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Check the K-factor against the ripple amplitude to estimate core loss.
    • Account for the lower permeability of iron powder in the turns count and DCR.
    • Verify the footprint against the recommended pad layout.

    Frequently Asked Questions

    What core loss should I expect?
    Read the core-loss curve at the flux amplitude implied by the K-factor and the ripple, at the switching frequency. Core loss is quoted per unit volume, so compare curves rather than single numbers.

    Is the saturation curve linear?
    No – it is deliberately soft. Inductance droops progressively above the rated current, which is why the ripple calculation should use the inductance at the actual bias, not the headline value.

    What does the K-factor tell me?
    It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.