| Parameter | Value |
|---|---|
| Orderable part number | HCP0805-1R5-R |
| OCL (open circuit inductance) | 1.5 uH ±20% |
| FLL minimum, at Isat | 0.96 uH |
| Irms (DC, 40 °C rise) | 13.3 A |
| Isat (20% rolloff @ +25 °C) | 18 A |
| DCR typical @ +20 °C | 6.8 mOhm |
| K-factor (Bp-p = K x L x dI) | 202, Bp-p in Gauss |
| Package | 7.9 x 7.6 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4349 |

Drawing reproduced from Eaton Technical Data 4349: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This part trades inductance per unit volume for current handling: iron powder saturates at a much higher flux density than ferrite, and the soft curve means the converter still has inductance at peak current. Standard choice for multiphase buck stages and battery power systems.
Copper loss at the rated current works out to roughly 1.2 W from a typical DCR of 6.8 mOhm at 13.3 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
At Isat the part holds about 243 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 202 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 303 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.
Within the HCP0805 family this is value 4 of 5, in a range that runs from 0.4 uH to 2.2 uH.
Compared with its neighbours in the table, HCP0805-2R2-R trades 4.5 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 6.8 mOhm becomes roughly 9.61 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.
What core loss should I expect?
Read the core-loss curve at the flux amplitude implied by the K-factor and the ripple, at the switching frequency. Core loss is quoted per unit volume, so compare curves rather than single numbers.
Is the saturation curve linear?
No – it is deliberately soft. Inductance droops progressively above the rated current, which is why the ripple calculation should use the inductance at the actual bias, not the headline value.
What does the K-factor tell me?
It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd