| Parameter | Value |
|---|---|
| Orderable part number | HCP0805-2R2-R |
| OCL (open circuit inductance) | 2.2 uH ±20% |
| FLL minimum, at Isat | 1.41 uH |
| Irms (DC, 40 °C rise) | 10 A |
| Isat (20% rolloff @ +25 °C) | 14 A |
| DCR typical @ +20 °C | 11.2 mOhm |
| K-factor (Bp-p = K x L x dI) | 175, Bp-p in Gauss |
| Package | 7.9 x 7.6 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4349 |

Drawing reproduced from Eaton Technical Data 4349: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Iron powder core in a shielded surface-mount body: the material gives a soft saturation curve, so inductance falls gradually with current rather than dropping off a cliff. The part is aimed at VRM and point-of-load stages where the inductor spends its working life part-way up the saturation curve.
With 11.2 mOhm typical, the I-squared-R loss at the full 10 A rating is about 1.12 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
The core stores roughly 216 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 175 means the flux swing is about 385 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.
In the HCP0805 line-up this part is number 5 of 5 by inductance, between 0.4 uH and 2.2 uH.
Compared with its neighbours in the table, HCP0805-1R5-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 11.2 mOhm becomes roughly 15.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.
What does the K-factor tell me?
It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.
What does the K-factor tell me?
It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.
What core loss should I expect?
Read the core-loss curve at the flux amplitude implied by the K-factor and the ripple, at the switching frequency. Core loss is quoted per unit volume, so compare curves rather than single numbers.