| Parameter | Value |
|---|---|
| Orderable part number | HCPT1309-1R5-R |
| OCL (open circuit inductance) | 1.59 uH ±20% |
| Irms (DC, 40 °C rise) | 13.7 A |
| Isat (20% rolloff @ +20 °C) | 24.1 A |
| Isat2 (30% rolloff @ +20 °C) | 30.6 A |
| DCR typical @ +20 °C | 3.82 mOhm |
| K-factor (Bp-p = K x L x dI) | 51.4, Bp-p in Gauss |
| Package | 13.2 x 13.2 mm |
| Height | 9.0 mm |
| Mounting | Through-hole, vertical |
| Operating temperature | -40 °C to +105 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4138 |

Drawing reproduced from Eaton Technical Data 4138: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is a vertical through-hole inductor for high-current DC-DC stages. Powder core, two saturation columns (20% and 30% rolloff), and a DCR in the fractions of a milliohm: the part is built for the main output inductor of a multiphase regulator on a board that still uses wave or selective soldering.
With 3.82 mOhm typical, the I-squared-R loss at the full 13.7 A rating is about 0.717 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +20 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 462 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 51.4 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 81.7 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The second saturation column, 30.6 A at 30% rolloff @ +20 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCPT family is the through-hole, vertical-mount high-current range. It exists for boards that need maximum current per square millimetre and are assembled by wave or selective soldering rather than reflow.
Within the HCPT1309 family this is value 4 of 6, in a range that runs from 0.2 uH to 3.31 uH.
The next value up in the same family, HCPT1309-2R2-R, gives 2.27 uH at 12.5 A and DCR 4.1 mOhm: the extra inductance costs about 6.9 A of rated current.
Copper resistance rises with temperature, so at the +105 °C limit the maximum DCR of 3.82 mOhm becomes roughly 5.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the vertical body blocks airflow across the board. If the enclosure relies on lateral airflow, check the thermal path through the leads and the copper around them.
What are the two saturation figures?
The same peak current measured at two rolloff criteria – 20 % and 30 % of inductance. They are design boundaries, not damage limits.
Does the vertical body affect cooling?
It blocks lateral airflow, so the thermal path is through the leads and the copper around them. Check the joint temperature, not just the body temperature.
What are the two saturation figures?
The same peak current measured at two rolloff criteria – 20 % and 30 % of inductance. They are design boundaries, not damage limits.