| Parameter | Value |
|---|---|
| Orderable part number | HCPT1309-R20-R |
| OCL (open circuit inductance) | 0.20 uH ±20% |
| Irms (DC, 40 °C rise) | 43.1 A |
| Isat (20% rolloff @ +20 °C) | 72.2 A |
| Isat2 (30% rolloff @ +20 °C) | 90 A |
| DCR typical @ +20 °C | 0.426 mOhm |
| K-factor (Bp-p = K x L x dI) | 154, Bp-p in Gauss |
| Package | 13.2 x 13.2 mm |
| Height | 9.0 mm |
| Mounting | Through-hole, vertical |
| Operating temperature | -40 °C to +105 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4138 |

Drawing reproduced from Eaton Technical Data 4138: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Vertical through-hole mounting puts the core axis perpendicular to the board, so the part occupies less board area than a flat inductor of the same volume. That is the reason this family exists: current density per square millimetre, at the cost of a taller profile.
The DCR figure of 0.426 mOhm is what sets the efficiency: at 43.1 A the winding drops about 0.018 mV and dissipates 0.791 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
Isat is specified as 20% rolloff @ +20 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Energy storage at the saturation current is around 521 uJ, the number that connects the inductance and the current rating into a single transient figure.
K-factor 154 means the flux swing is about 30.8 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The second saturation column, 90 A at 30% rolloff @ +20 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCPT family is the through-hole, vertical-mount high-current range. It exists for boards that need maximum current per square millimetre and are assembled by wave or selective soldering rather than reflow.
The HCPT1309 family spans 0.2 uH to 3.31 uH; this row sits at position 1 of 6.
The next value up in the same family, HCPT1309-R47-R, gives 0.49 uH at 34 A and DCR 0.624 mOhm: the extra inductance costs about 0 A of rated current.
Copper resistance rises with temperature, so at the +105 °C limit the maximum DCR of 0.426 mOhm becomes roughly 0.568 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the vertical body blocks airflow across the board. If the enclosure relies on lateral airflow, check the thermal path through the leads and the copper around them.
What are the two saturation figures?
The same peak current measured at two rolloff criteria – 20 % and 30 % of inductance. They are design boundaries, not damage limits.
Does the vertical body affect cooling?
It blocks lateral airflow, so the thermal path is through the leads and the copper around them. Check the joint temperature, not just the body temperature.
How does the vertical body affect the magnetic field?
The core axis is perpendicular to the board, so the fringing field is directed differently from a flat part. Check the orientation against any magnetic sensor on the board.