| Parameter | Value |
|---|---|
| Orderable part number | HCSA1V1008-100-R |
| Inductance | 10.0 uH ±20% |
| DCR maximum @ +25 °C | 35.8 mOhm |
| Irms (DC, 40 °C rise) | 5 A |
| Isat | 11.2 A |
| FLL minimum (at Isat) | 5.6 uH |
| SRF typical | 8.4 MHz |
| K-factor | 39 |
| Coupling coefficient | 0.95 |
| SCL (secondary inductance) | 0.3 uH |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1085 |

Drawing reproduced from Eaton Technical Data ELX1085: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.
At 5 A the winding dissipates about 0.895 W in copper, using the 35.8 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 11.2 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
Within the HCSA1V1008 family this is value 1 of 3, in a range that runs from 10 to 22 uH.
The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.
What is the difference between Irms and Isat?
Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.
How much inductance is left at rated current?
The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.
Why are there two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.