Eaton HFW1V2211H8R2K 8.2 uH Power Inductor, 15 A
Eaton HFW1V2211H8R2K 8.2 uH Power Inductor, 15 A

Eaton HFW1V2211H8R2K 8.2 uH Power Inductor, 15 A

Share
HFW1V2211H8R2K: high-current power inductor, 8.2 uH, 15 A, Isat 24 A, DCR 18.5 mOhm.
    • Product Details
    • Download

    Eaton HFW1V2211H8R2K 8.2 uH Power Inductor, 15 A

    HFW1V2211H8R2K at a glance: high-current power inductor, 8.2 uH, 15 A, Isat 24 A, DCR 18.5 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberHFW1V2211H8R2K
    Inductance8.2 uH ±20%
    DCR maximum @ +25 °C18.5 mOhm
    Irms (DC, 40 °C rise)15 A
    Isat24 A
    SRF typical3.4 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1331

    Outline Drawing

    HFW1V2211H8R2K mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1331: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    How to Read These Ratings

    The part is built around a distributed-gap core: the energy is stored through the volume of the magnetic material rather than in a single discrete gap, which is what produces the gradual rolloff and the low fringing field. Copper loss and core loss are traded against each other in the winding and body proportions.

    At 15 A the winding dissipates about 4.16 W in copper, using the 18.5 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 24 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HFW1V2211H8R2K family this is value 1 of 1, in a range that runs from 8.2 to 8.2 uH.

    Series Positioning

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: computing (pol/vrms); distributed power architectures; servers and workstations; lan / wan applications; game consoles.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products