Eaton HFW1V2815H100K 10.0 uH Power Inductor, 12 A
Eaton HFW1V2815H100K 10.0 uH Power Inductor, 12 A

Eaton HFW1V2815H100K 10.0 uH Power Inductor, 12 A

Share
HFW1V2815H100K: high-current power inductor, 10.0 uH, 12 A, Isat 30 A, DCR 21.5 mOhm.
    • Product Details
    • Download

    Eaton HFW1V2815H100K 10.0 uH Power Inductor, 12 A

    HFW1V2815H100K at a glance: high-current power inductor, 10.0 uH, 12 A, Isat 30 A, DCR 21.5 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberHFW1V2815H100K
    Inductance10.0 uH ±20%
    DCR maximum @ +25 °C21.5 mOhm
    Irms (DC, 40 °C rise)12 A
    Isat30 A
    SRF typical2.05 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1330

    Mechanical Dimensions & Pad Layout

    HFW1V2815H100K mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1330: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    How to Read These Ratings

    A shielded power inductor with a soft saturation curve: as the current rises the inductance droops rather than collapsing, so the regulator keeps control through a load transient. The molded body contains the field, which is why these parts can sit side by side on a multiphase rail without coupling into each other.

    At 12 A the winding dissipates about 3.1 W in copper, using the 21.5 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 30 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HFW1V2815H100K family this is value 1 of 1, in a range that runs from 10 to 10 uH.

    Where This Series Fits

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: computing (pol/vrms); distributed power architectures; servers and workstations; lan / wan applications; game consoles.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products