Eaton HPAL1V0630-1R5-R 1.5 uH High-Current Inductor
Eaton HPAL1V0630-1R5-R 1.5 uH High-Current Inductor

Eaton HPAL1V0630-1R5-R 1.5 uH High-Current Inductor

Share
HPAL1V0630-1R5-R: high-current power inductor, 1.5 uH, 12 A, Isat 12 A, DCR 10 mOhm.
    • Product Details
    • Download

    Eaton HPAL1V0630-1R5-R 1.5 uH High-Current Inductor

    HPAL1V0630-1R5-R at a glance: high-current power inductor, 1.5 uH, 12 A, Isat 12 A, DCR 10 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHPAL1V0630-1R5-R
    Inductance1.5 uH ±20%
    DCR maximum @ +25 °C10 mOhm
    Irms (DC, 40 °C rise)12 A
    Isat12 A
    FLL minimum (at Isat)0.84 uH
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 11080

    Mechanical Drawing

    Outline drawing and pad layout are on page 2 of Eaton Technical Data 11080; the package column above gives the body size in millimetres.

    What the Numbers Mean

    A shielded power inductor with a soft saturation curve: as the current rises the inductance droops rather than collapsing, so the regulator keeps control through a load transient. The molded body contains the field, which is why these parts can sit side by side on a multiphase rail without coupling into each other.

    At 12 A the winding dissipates about 1.44 W in copper, using the 10 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 12 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HPAL1V0630 family this is value 9 of 16, in a range that runs from 0.15 to 10 uH.

    Positioning in the Range

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules (pol); desktop and server vrms and evrds; base station equipment.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.