Eaton HPAL1V0630-5R6-R 5.6 uH High-Current Inductor
Eaton HPAL1V0630-5R6-R 5.6 uH High-Current Inductor

Eaton HPAL1V0630-5R6-R 5.6 uH High-Current Inductor

Share
HPAL1V0630-5R6-R: high-current power inductor, 5.6 uH, 5.5 A, Isat 6.5 A, DCR 35 mOhm.
    • Product Details
    • Download

    Eaton HPAL1V0630-5R6-R 5.6 uH High-Current Inductor

    HPAL1V0630-5R6-R at a glance: high-current power inductor, 5.6 uH, 5.5 A, Isat 6.5 A, DCR 35 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHPAL1V0630-5R6-R
    Inductance5.6 uH ±20%
    DCR maximum @ +25 °C35 mOhm
    Irms (DC, 40 °C rise)5.5 A
    Isat6.5 A
    FLL minimum (at Isat)3.14 uH
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 11080

    Outline Drawing

    Outline drawing and pad layout are on page 2 of Eaton Technical Data 11080; the package column above gives the body size in millimetres.

    The Figures Explained

    This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.

    At 5.5 A the winding dissipates about 1.06 W in copper, using the 35 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 6.5 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HPAL1V0630 family this is value 13 of 16, in a range that runs from 0.15 to 10 uH.

    Series Positioning

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules (pol); desktop and server vrms and evrds; base station equipment.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products