| Parameter | Value |
|---|---|
| Orderable part number | HPAL1V1040-4R7-R |
| Inductance | 4.7 uH ±20% |
| DCR maximum @ +25 °C | 13 mOhm |
| Irms (DC, 40 °C rise) | 9 A |
| Isat | 13 A |
| FLL minimum (at Isat) | 2.64 uH |
| SRF typical | 17 MHz |
| K-factor | 169 |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 11083 |
Outline drawing and pad layout are on page 2 of Eaton Technical Data 11083; the package column above gives the body size in millimetres.
This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.
At 9 A the winding dissipates about 1.05 W in copper, using the 13 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 13 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
Within the HPAL1V1040 family this is value 12 of 19, in a range that runs from 0.22 to 47 uH.
The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.
What is the difference between Irms and Isat?
Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.
Why are there two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.
What is the difference between Irms and Isat?
Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.