Eaton LAN1VSOPS16351C2 Network Transformer
Eaton LAN1VSOPS16351C2 Network Transformer

Eaton LAN1VSOPS16351C2 Network Transformer

Share
LAN1VSOPS16351C2: LAN transformer, single port.
    • Product Details
    • Download

    Eaton LAN1VSOPS16351C2 Network Transformer

    LAN1VSOPS16351C2 at a glance: LAN transformer, single port.

    Electrical Specifications

    ParameterValue
    Orderable part numberLAN1VSOPS16351C2
    PortsSingle
    Pins16
    Leakage inductance0.5 uH
    DCR maximum1.4 Ohm
    Inter-winding capacitance35 pF
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +85 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1374

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1374; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    Ethernet magnetics are specified in the frequency domain, not at DC. Insertion loss and return loss over the band matter more than the inductance number, which is only there to guarantee the low-frequency corner.

    Within the LAN1VSOPS16351C2 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.

    • The magnetics set the return loss and crosstalk floor of the link. A marginal part cannot be fixed in layout.
    • Typical applications: selv/elv equipment; ip telephones; wireless lan access point; iot, remote monitoring; smart tv.
    • Design note: insertion loss and return loss are band specifications. Compare curves at the band edges, not the typical number.

    Frequently Asked Questions

    Does the part include the common mode choke?
    Only where the part number or the description says so. Many designs use a separate choke; the PoE variants with a CMC in the same package are marked as such.

    What is CWW?
    Inter-winding capacitance. It is the path that lets common mode noise through the transformer, so lower is better for EMC. It is a construction parameter, not something the layout can fix.

    Which port count do I need?
    One transformer per port. The single, dual and quad variants are the same magnetics repeated in one package, which is why the pin count scales with the port count.