Eaton LAN2VSOPD48351C2 Network Transformer
Eaton LAN2VSOPD48351C2 Network Transformer

Eaton LAN2VSOPD48351C2 Network Transformer

Share
LAN2VSOPD48351C2: LAN transformer, dual port.
    • Product Details
    • Download

    Eaton LAN2VSOPD48351C2 Network Transformer

    LAN2VSOPD48351C2 at a glance: LAN transformer, dual port.

    Specification Table

    ParameterValue
    Orderable part numberLAN2VSOPD48351C2
    PortsDual
    Pins48
    Leakage inductance10.8 uH
    DCR maximum600 mOhm
    Inter-winding capacitance35 pF
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +85 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1376

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1376; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A LAN transformer provides the isolation and the common mode rejection between the cable and the PHY. The turns ratio is fixed at 1CT:1CT for Ethernet, so the design work is in the inductance, the leakage and the inter-winding capacitance – those three set insertion loss, return loss and crosstalk.

    Within the LAN2VSOPD48351C2 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.

    • The magnetics set the return loss and crosstalk floor of the link. A marginal part cannot be fixed in layout.
    • Typical applications: selv/elv equipment; ip telephones; wireless lan access point; iot, remote monitoring; smart tv.
    • Design note: insertion loss and return loss are band specifications. Compare curves at the band edges, not the typical number.

    Frequently Asked Questions

    Why is inductance quoted at a DC bias?
    The PHY or the PoE feed pushes a DC current through the winding, and the core saturates a little. The bias condition in the table is the one the number applies to; without it the figure is meaningless.

    What does 1CT:1CT mean?
    Centre-tapped to centre-tapped, one to one. Ethernet PHYs are designed around this ratio, so a different ratio changes the impedance seen by the PHY and the link will not meet its return loss specification.

    Does the part include the common mode choke?
    Only where the part number or the description says so. Many designs use a separate choke; the PoE variants with a CMC in the same package are marked as such.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message