Eaton LAN2VSOPS24351C2 Single-Port LAN Transformer
Eaton LAN2VSOPS24351C2 Single-Port LAN Transformer

Eaton LAN2VSOPS24351C2 Single-Port LAN Transformer

Share
LAN2VSOPS24351C2: LAN transformer, single port.
    • Product Details
    • Download

    Eaton LAN2VSOPS24351C2 Single-Port LAN Transformer

    LAN2VSOPS24351C2 at a glance: LAN transformer, single port.

    Electrical Specifications

    ParameterValue
    Orderable part numberLAN2VSOPS24351C2
    PortsSingle
    Pins24
    Leakage inductance13 uH
    DCR maximum1.4 Ohm
    Inter-winding capacitance35 pF
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +85 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1376

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1376; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The magnetics in an Ethernet port do three jobs: isolate the PHY from the cable, block common mode noise, and match the line. This part is the transformer half, and the ports, pins and channel count are what decide whether it fits the connector pinout.

    Within the LAN2VSOPS24351C2 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.

    • The magnetics set the return loss and crosstalk floor of the link. A marginal part cannot be fixed in layout.
    • Typical applications: selv/elv equipment; ip telephones; wireless lan access point; iot, remote monitoring; smart tv.
    • Design note: insertion loss and return loss are band specifications. Compare curves at the band edges, not the typical number.

    Frequently Asked Questions

    What is CWW?
    Inter-winding capacitance. It is the path that lets common mode noise through the transformer, so lower is better for EMC. It is a construction parameter, not something the layout can fix.

    What does 1CT:1CT mean?
    Centre-tapped to centre-tapped, one to one. Ethernet PHYs are designed around this ratio, so a different ratio changes the impedance seen by the PHY and the link will not meet its return loss specification.

    Which port count do I need?
    One transformer per port. The single, dual and quad variants are the same magnetics repeated in one package, which is why the pin count scales with the port count.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message