Eaton LAN3VSOS24151C2 Network Transformer
Eaton LAN3VSOS24151C2 Network Transformer

Eaton LAN3VSOS24151C2 Network Transformer

Share
LAN3VSOS24151C2: LAN transformer, single port.
    • Product Details
    • Download

    Eaton LAN3VSOS24151C2 Network Transformer

    LAN3VSOS24151C2 at a glance: LAN transformer, single port.

    Key Specifications

    ParameterValue
    Orderable part numberLAN3VSOS24151C2
    PortsSingle
    Pins24
    Leakage inductance0.5 uH
    DCR maximum1.2 Ohm
    Inter-winding capacitance35 pF
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +85 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1378

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1378; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    Ethernet magnetics are specified in the frequency domain, not at DC. Insertion loss and return loss over the band matter more than the inductance number, which is only there to guarantee the low-frequency corner.

    Within the LAN3VSOS24151C2 family this is item 1 of 1 in the Eaton catalogue.

    What This Family Is For

    The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.

    • The magnetics set the return loss and crosstalk floor of the link. A marginal part cannot be fixed in layout.
    • Typical applications: rj45 network interface card; ethernet switch, router; selv/elv equipment; smart tv; data centers.
    • Design note: insertion loss and return loss are band specifications. Compare curves at the band edges, not the typical number.

    Frequently Asked Questions

    What does 1CT:1CT mean?
    Centre-tapped to centre-tapped, one to one. Ethernet PHYs are designed around this ratio, so a different ratio changes the impedance seen by the PHY and the link will not meet its return loss specification.

    Why is inductance quoted at a DC bias?
    The PHY or the PoE feed pushes a DC current through the winding, and the core saturates a little. The bias condition in the table is the one the number applies to; without it the figure is meaningless.

    Why is inductance quoted at a DC bias?
    The PHY or the PoE feed pushes a DC current through the winding, and the core saturates a little. The bias condition in the table is the one the number applies to; without it the figure is meaningless.