Eaton LAN4VSOS24151C2 Ethernet Isolation Transformer
Eaton LAN4VSOS24151C2 Ethernet Isolation Transformer

Eaton LAN4VSOS24151C2 Ethernet Isolation Transformer

Share
LAN4VSOS24151C2: LAN transformer, single port.
    • Product Details
    • Download

    Eaton LAN4VSOS24151C2 Ethernet Isolation Transformer

    LAN4VSOS24151C2 at a glance: LAN transformer, single port.

    Ratings at a Glance

    ParameterValue
    Orderable part numberLAN4VSOS24151C2
    PortsSingle
    Pins24
    Leakage inductance0.5 uH
    DCR maximum1.2 Ohm
    Inter-winding capacitance35 pF
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +85 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1380

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1380; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A LAN transformer provides the isolation and the common mode rejection between the cable and the PHY. The turns ratio is fixed at 1CT:1CT for Ethernet, so the design work is in the inductance, the leakage and the inter-winding capacitance – those three set insertion loss, return loss and crosstalk.

    Within the LAN4VSOS24151C2 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.

    • The magnetics set the return loss and crosstalk floor of the link. A marginal part cannot be fixed in layout.
    • Typical applications: rj45 network interface card; ethernet switch, router; selv/elv equipment; smart tv; data centers.
    • Design note: insertion loss and return loss are band specifications. Compare curves at the band edges, not the typical number.

    Frequently Asked Questions

    Why is inductance quoted at a DC bias?
    The PHY or the PoE feed pushes a DC current through the winding, and the core saturates a little. The bias condition in the table is the one the number applies to; without it the figure is meaningless.

    What does 1CT:1CT mean?
    Centre-tapped to centre-tapped, one to one. Ethernet PHYs are designed around this ratio, so a different ratio changes the impedance seen by the PHY and the link will not meet its return loss specification.

    What is CWW?
    Inter-winding capacitance. It is the path that lets common mode noise through the transformer, so lower is better for EMC. It is a construction parameter, not something the layout can fix.