Eaton MCL1005-151-R 150.0 nH Multilayer Inductor 100
Eaton MCL1005-151-R 150.0 nH Multilayer Inductor 100

Eaton MCL1005-151-R 150.0 nH Multilayer Inductor 100

Share
MCL1005-151-R: multilayer chip inductor, 150.0 nH 100, Q 100, SRF 8 MHz, 3 mA, DCR 550000 mOhm.
    • Product Details
    • Download

    Eaton MCL1005-151-R 150.0 nH Multilayer Inductor 100

    MCL1005-151-R at a glance: multilayer chip inductor, 150.0 nH 100, Q 100, SRF 8 MHz, 3 mA, DCR 550000 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMCL1005-151-R
    Inductance150.0 nH 100
    Q minimum100
    DCR maximum @ +25 °C550000 mOhm
    Rated current maximum3 mA
    SRF minimum8 MHz
    Test frequency50 MHz
    Package1.0 x 0.5 mm
    Size code1005 (0402)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10925

    Mechanical Drawing

    MCL1005-151-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10925: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    How to Read These Ratings

    The inductance here is a few nanohenry, which puts the part in RF and high-speed digital territory: matching networks, filter sections, bias chokes on amplifier supplies, and the small isolation inductors that keep clock harmonics out of connectors. The multilayer body keeps the parasitics predictable, and the Q column tells you how much loss the part adds at the test frequency.

    The row reads 150.0 nH 100 with a minimum Q of 100 at 50 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 100 means the part’s loss is about 1 % of its reactance in that band.

    Self-resonance is quoted as 8 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 8 MHz is the design headroom.

    Within the MCL1005 family this is value 41 of 46, in a range that runs from 0.001 to 0.36 nH.

    Where This Series Fits

    The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.

    • The rated current is a thermal limit for the part in free air, not a saturation limit. At high ambient the current has to be derated.
    • Typical applications: industrial connectivity (iot); wireless communiations; bluetooth; wifi; antenna.
    • Design note: compare SRF against the highest frequency the circuit will see, not just the fundamental.

    Frequently Asked Questions

    How much does the value drift with temperature?
    The data sheet gives the tolerance band; the drift inside that band is small for this construction because there is no mechanical winding to move.

    Why is the inductance quoted at a test frequency?
    At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.

    Can I replace a wire-wound chip with this part?
    Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.