| Parameter | Value |
|---|---|
| Orderable part number | MCL1005-181-R |
| Inductance | 180.0 nH 100 |
| Q minimum | 100 |
| DCR maximum @ +25 °C | 500000 mOhm |
| Rated current maximum | 4 mA |
| SRF minimum | 8 MHz |
| Test frequency | 50 MHz |
| Package | 1.0 x 0.5 mm |
| Size code | 1005 (0402) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10925 |

Drawing reproduced from Eaton Technical Data 10925: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
The inductance here is a few nanohenry, which puts the part in RF and high-speed digital territory: matching networks, filter sections, bias chokes on amplifier supplies, and the small isolation inductors that keep clock harmonics out of connectors. The multilayer body keeps the parasitics predictable, and the Q column tells you how much loss the part adds at the test frequency.
The row reads 180.0 nH 100 with a minimum Q of 100 at 50 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 100 means the part’s loss is about 1 % of its reactance in that band.
Self-resonance is quoted as 8 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 8 MHz is the design headroom.
Within the MCL1005 family this is value 42 of 46, in a range that runs from 0.001 to 0.36 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
How much does the value drift with temperature?
The data sheet gives the tolerance band; the drift inside that band is small for this construction because there is no mechanical winding to move.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd