| Parameter | Value |
|---|---|
| Orderable part number | MCL1005-9R1-R |
| Inductance | 9.1 nH 300 |
| Q minimum | 100 |
| DCR maximum @ +25 °C | 3400000 mOhm |
| Rated current maximum | 0 mA |
| SRF minimum | 8 MHz |
| Test frequency | 50 MHz |
| Package | 1.0 x 0.5 mm |
| Size code | 1005 (0402) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10925 |

Drawing reproduced from Eaton Technical Data 10925: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
A multilayer chip inductor is a coil printed in layers of ceramic and metal, fired into a single body. There is no winding to buzz or shift, the inductance is set by the printed pattern, and the part sits on the board like any other 0402 or 0603 component. That construction is why these parts are used wherever the value is small and the quantity is large.
The row reads 9.1 nH 300 with a minimum Q of 100 at 50 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 100 means the part’s loss is about 1 % of its reactance in that band.
Self-resonance is quoted as 8 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 8 MHz is the design headroom.
Within the MCL1005 family this is value 24 of 46, in a range that runs from 0.001 to 0.36 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.