| Parameter | Value |
|---|---|
| Orderable part number | MCL2012V1-100-R |
| Inductance | 10.0 uH |
| DCR maximum @ +25 °C | 650 mOhm |
| Rated current maximum | 100 mA |
| SRF minimum | 24 MHz |
| Test frequency | 1 MHz |
| Test voltage | 50 mV |
| Package | 2.0 x 1.25 mm |
| Size code | 2012 (0805) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10928 |

Drawing reproduced from Eaton Technical Data 10928: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
This is a surface-mount multilayer inductor: printed coil, sintered body, silver terminations. The value is quoted at a defined test frequency because at these inductances the measurement conditions matter as much as the part.
The row reads 10.0 uH with a minimum Q of – at 1 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of – means the part’s loss is about 100 % of its reactance in that band.
Self-resonance is quoted as 24 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 24 MHz is the design headroom.
Within the MCL2012V1 family this is value 29 of 33, in a range that runs from 0.047 to 22 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.