MCL2012V1-R068-R: multilayer chip inductor, 0.068 nH , Q -, SRF 280 MHz, 350 mA, DCR 200 mOhm.
    • Product Details
    • Download

    Eaton MCL2012V1-R068-R 0.068 nH Chip Inductor, – Q

    MCL2012V1-R068-R at a glance: multilayer chip inductor, 0.068 nH , Q -, SRF 280 MHz, 350 mA, DCR 200 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberMCL2012V1-R068-R
    Inductance0.068 nH
    DCR maximum @ +25 °C200 mOhm
    Rated current maximum350 mA
    SRF minimum280 MHz
    Test frequency1 MHz
    Test voltage50 mV
    Package2.0 x 1.25 mm
    Size code2012 (0805)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10928

    Dimensions and Pad Layout

    MCL2012V1-R068-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10928: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    The Figures Explained

    This is a surface-mount multilayer inductor: printed coil, sintered body, silver terminations. The value is quoted at a defined test frequency because at these inductances the measurement conditions matter as much as the part.

    The row reads 0.068 nH with a minimum Q of – at 1 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of – means the part’s loss is about 100 % of its reactance in that band.

    Self-resonance is quoted as 280 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 280 MHz is the design headroom.

    Within the MCL2012V1 family this is value 3 of 33, in a range that runs from 0.047 to 22 nH.

    Where This Series Fits

    The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.

    • The rated current is a thermal limit for the part in free air, not a saturation limit. At high ambient the current has to be derated.
    • Typical applications: industrial connectivity (iot); wireless communiations; bluetooth; wifi; antenna.
    • Design note: compare SRF against the highest frequency the circuit will see, not just the fundamental.

    Frequently Asked Questions

    Why is the inductance quoted at a test frequency?
    At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.

    Why is the inductance quoted at a test frequency?
    At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.

    What happens above the self-resonant frequency?
    The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products