MCL2012V2-3R3-R: multilayer chip inductor, 3.3 nH 0.3nH, Q 12, SRF 5000 MHz, 500 mA, DCR 130 mOhm.
    • Product Details
    • Download

    Eaton MCL2012V2-3R3-R 3.3 nH Multilayer Inductor 0.3nH

    MCL2012V2-3R3-R at a glance: multilayer chip inductor, 3.3 nH 0.3nH, Q 12, SRF 5000 MHz, 500 mA, DCR 130 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMCL2012V2-3R3-R
    Inductance3.3 nH 0.3nH
    Q minimum12
    DCR maximum @ +25 °C130 mOhm
    Rated current maximum500 mA
    SRF minimum5000 MHz
    Test frequency100 MHz
    Test voltage50 mV
    Package2.0 x 1.25 mm
    Size code2012 (0805)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10929

    Mechanical Dimensions & Pad Layout

    MCL2012V2-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10929: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    The Figures Explained

    This is a surface-mount multilayer inductor: printed coil, sintered body, silver terminations. The value is quoted at a defined test frequency because at these inductances the measurement conditions matter as much as the part.

    The row reads 3.3 nH 0.3nH with a minimum Q of 12 at 100 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 12 means the part’s loss is about 8.33 % of its reactance in that band.

    Self-resonance is quoted as 5000 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 5000 MHz is the design headroom.

    Within the MCL2012V2 family this is value 6 of 32, in a range that runs from 0.002 to 0.47 nH.

    What This Family Is For

    The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.

    • The rated current is a thermal limit for the part in free air, not a saturation limit. At high ambient the current has to be derated.
    • Typical applications: industrial connectivity (iot); wireless communiations; bluetooth; wifi; antenna.
    • Design note: compare SRF against the highest frequency the circuit will see, not just the fundamental.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.

    Can I replace a wire-wound chip with this part?
    Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.

    Why is the inductance quoted at a test frequency?
    At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.