| Parameter | Value |
|---|---|
| Orderable part number | MCL2012V2-4R7-R |
| Inductance | 4.7 nH ±0.3nH |
| Q minimum | 12 |
| DCR maximum @ +25 °C | 200 mOhm |
| Rated current maximum | 500 mA |
| SRF minimum | 4000 MHz |
| Test frequency | 100 MHz |
| Test voltage | 50 mV |
| Package | 2.0 x 1.25 mm |
| Size code | 2012 (0805) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10929 |

Drawing reproduced from Eaton Technical Data 10929: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
Where a circuit needs a small, stable inductance in a package measured in millimetres, the multilayer chip is the default. Its self-resonant frequency is the practical ceiling – above it the part behaves like a capacitor, so the SRF column is the first thing to check against the operating band.
The row reads 4.7 nH ±0.3nH with a minimum Q of 12 at 100 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 12 means the part’s loss is about 8.33 % of its reactance in that band.
Self-resonance is quoted as 4000 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 4000 MHz is the design headroom.
Within the MCL2012V2 family this is value 8 of 32, in a range that runs from 0.002 to 0.47 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
How much does the value drift with temperature?
The data sheet gives the tolerance band; the drift inside that band is small for this construction because there is no mechanical winding to move.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.