| Parameter | Value |
|---|---|
| Orderable part number | MCL2V0603-121-R |
| Inductance | 120.0 nH ±5% |
| Q minimum | 10 |
| DCR maximum @ +25 °C | 5000 mOhm |
| Rated current maximum | 50 mA |
| SRF minimum | 1000 MHz |
| Test frequency | 300 MHz |
| Test voltage | 50 mV |
| Package | 0.6 x 0.3 mm |
| Size code | 0603 (0201) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 11227 |

Drawing reproduced from Eaton Technical Data 11227: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
The inductance here is a few nanohenry, which puts the part in RF and high-speed digital territory: matching networks, filter sections, bias chokes on amplifier supplies, and the small isolation inductors that keep clock harmonics out of connectors. The multilayer body keeps the parasitics predictable, and the Q column tells you how much loss the part adds at the test frequency.
The row reads 120.0 nH ±5% with a minimum Q of 10 at 300 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 10 means the part’s loss is about 10 % of its reactance in that band.
Self-resonance is quoted as 1000 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 1000 MHz is the design headroom.
Within the MCL2V0603 family this is value 62 of 62, in a range that runs from 0.001 to 0.12 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd