| Parameter | Value |
|---|---|
| Orderable part number | MCLA1005V2-1R8-R |
| Inductance | 1.8 nH ±0.3nH |
| Q minimum | 8 |
| DCR maximum @ +25 °C | 120 mOhm |
| Rated current maximum | 300 mA |
| SRF minimum | 6000 MHz |
| Test frequency | 100 MHz |
| Test voltage | 50 mV |
| Package | 1.0 x 0.5 mm |
| Size code | 1005 (0402) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10974 |

Drawing reproduced from Eaton Technical Data 10974: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
The inductance here is a few nanohenry, which puts the part in RF and high-speed digital territory: matching networks, filter sections, bias chokes on amplifier supplies, and the small isolation inductors that keep clock harmonics out of connectors. The multilayer body keeps the parasitics predictable, and the Q column tells you how much loss the part adds at the test frequency.
The row reads 1.8 nH ±0.3nH with a minimum Q of 8 at 100 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 8 means the part’s loss is about 12.5 % of its reactance in that band.
Self-resonance is quoted as 6000 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 6000 MHz is the design headroom.
Within the MCLA1005V2 family this is value 7 of 45, in a range that runs from 0.001 to 0.33 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd