Eaton MCLA2012V1-6R8-R 6.8 uH Chip Inductor 0805
Eaton MCLA2012V1-6R8-R 6.8 uH Chip Inductor 0805

Eaton MCLA2012V1-6R8-R 6.8 uH Chip Inductor 0805

Share
MCLA2012V1-6R8-R: multilayer chip inductor, 6.8 uH ±10, Q 30, SRF 29 MHz, 15 mA, DCR 1050 mOhm.
    • Product Details
    • Download

    Eaton MCLA2012V1-6R8-R 6.8 uH Chip Inductor 0805

    MCLA2012V1-6R8-R at a glance: multilayer chip inductor, 6.8 uH ±10, Q 30, SRF 29 MHz, 15 mA, DCR 1050 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberMCLA2012V1-6R8-R
    Inductance6.8 uH ±10
    Q minimum30
    DCR maximum @ +25 °C1050 mOhm
    Rated current maximum15 mA
    SRF minimum29 MHz
    Test frequency4 MHz
    Test voltage50 mV
    Package2.0 x 1.25 mm
    Size code2012 (0805)
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10977

    Mechanical Dimensions & Pad Layout

    Outline drawing and pad layout are on page 2 of Eaton Technical Data 10977; the package column above gives the body size in millimetres.

    The Figures Explained

    This is a surface-mount multilayer inductor: printed coil, sintered body, silver terminations. The value is quoted at a defined test frequency because at these inductances the measurement conditions matter as much as the part.

    The row reads 6.8 uH ±10 with a minimum Q of 30 at 4 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 30 means the part’s loss is about 3.33 % of its reactance in that band.

    Self-resonance is quoted as 29 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 29 MHz is the design headroom.

    Within the MCLA2012V1 family this is value 27 of 30, in a range that runs from 0.047 to 12 nH.

    What This Family Is For

    The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.

    • The rated current is a thermal limit for the part in free air, not a saturation limit. At high ambient the current has to be derated.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: compare SRF against the highest frequency the circuit will see, not just the fundamental.

    Frequently Asked Questions

    Why is the inductance quoted at a test frequency?
    At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.

    Can I replace a wire-wound chip with this part?
    Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.

    Why is the inductance quoted at a test frequency?
    At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.