| Parameter | Value |
|---|---|
| Orderable part number | MCLA3216V1-4R7-R |
| Inductance | 4.7 uH ±10 |
| Q minimum | 35 |
| DCR maximum @ +25 °C | 650 mOhm |
| Rated current maximum | 25 mA |
| SRF minimum | 35 MHz |
| Test frequency | 10 MHz |
| Test voltage | 50 mV |
| Package | 3.2 x 1.6 mm |
| Size code | 3216 (1206) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10978 |
Outline drawing and pad layout are on page 2 of Eaton Technical Data 10978; the package column above gives the body size in millimetres.
Where a circuit needs a small, stable inductance in a package measured in millimetres, the multilayer chip is the default. Its self-resonant frequency is the practical ceiling – above it the part behaves like a capacitor, so the SRF column is the first thing to check against the operating band.
The row reads 4.7 uH ±10 with a minimum Q of 35 at 10 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 35 means the part’s loss is about 2.86 % of its reactance in that band.
Self-resonance is quoted as 35 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 35 MHz is the design headroom.
Within the MCLA3216V1 family this is value 25 of 30, in a range that runs from 0.047 to 12 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.