| Parameter | Rating |
|---|---|
| Part number | MDA-1-1/2-R |
| Body | Ceramic tube, 1/4 x 1-1/4 in (6.3 x 32 mm) |
| Element | single element |
| End caps | nickel-plated brass |
| Typical melting I2t | 3.4 A²s |
| Rated current | 1.5 A (1-1/2 A) |
| AC interrupting rating | 200 A at 250 Vac; 10,000 A at 125 Vac |
| Typical DC cold resistance | 190 mΩ |
| Maximum voltage drop | 370 mV |
| Voltage rating | 250 Vac |
| Design standard | UL 248-14 |
Typical places this fuse turns up:
What are the ratings of the MDA-1-1/2-R?
1.5 A continuous at 250 Vac, interrupting rating 200 A at 250 Vac; 10,000 A at 125 Vac.
Is the MDA-1-1/2-R fast-acting or time-delay?
It is slow-blow. It tolerates short inrush surges.
Can the MDA-1-1/2-R be used on a higher fault-current circuit?
No — its interrupting rating is 200 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.