Eaton MDA-3/4-R 750 mA Ceramic Tube Fuse, Time-Lag, 250 Vac
Eaton MDA-3/4-R 750 mA Ceramic Tube Fuse, Time-Lag, 250 Vac

Eaton MDA-3/4-R 750 mA Ceramic Tube Fuse, Time-Lag, 250 Vac

Share
pEaton MDA-3/4-R — 750 mA, 250 V, time-delay ceramic cartridge fuse, 200 A at 250 Vac; 10,000 A at 125 Vac interrupting./p
    • Product Details
    • Download

    Eaton MDA-3/4-R 750 mA Ceramic Tube Fuse, Time-Lag, 250 Vac

    Built by Eaton, the MDA-3/4-R carries 750 mA, rated 250 Vac, uses a time-delay element, in a ceramic body.

    Technical Data

    ParameterRating
    Part numberMDA-3/4-R
    Elementsingle element
    Voltage rating250 Vac
    End capsnickel-plated brass
    Typical melting I2t0.42 A²s
    Rated current750 mA (3/4 A)
    Design standardUL 248-14
    Maximum voltage drop495 mV
    AC interrupting rating200 A at 250 Vac; 10,000 A at 125 Vac
    Typical DC cold resistance520 mΩ
    BodyCeramic tube, 1/4 x 1-1/4 in (6.3 x 32 mm)

    Selection Notes

    • Interrupting capability is 200 A at 250 Vac; 10,000 A at 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 750 mA to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV

    Q&A

    What are the ratings of the MDA-3/4-R?

    750 mA continuous at 250 Vac, interrupting rating 200 A at 250 Vac; 10,000 A at 125 Vac.

    Is the MDA-3/4-R fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the MDA-3/4-R be used on a higher fault-current circuit?

    No — its interrupting rating is 200 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products