| Parameter | Rating |
|---|---|
| Part number | MDA-3-R |
| Voltage rating, DC | 125 Vdc |
| End caps | nickel-plated brass |
| Maximum voltage drop | 215 mV |
| Voltage rating | 250 Vac |
| Typical melting I2t | 15.9 A²s |
| Design standard | UL 248-14 |
| Typical DC cold resistance | 48 mΩ |
| AC interrupting rating | 200 A at 250 Vac; 10,000 A at 125 Vac |
| Body | Ceramic tube, 1/4 x 1-1/4 in (6.3 x 32 mm) |
| Element | single element |
| Rated current | 3 A |
Engineers usually specify it for these duties:
What are the ratings of the MDA-3-R?
3 A continuous at 125 Vdc, interrupting rating 200 A at 250 Vac; 10,000 A at 125 Vac.
Is the MDA-3-R fast-acting or time-delay?
It is slow-blow. It tolerates short inrush surges.
Can the MDA-3-R be used on a higher fault-current circuit?
No — its interrupting rating is 200 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.