Eaton MLVA02V05C033-R 5.5 V Multilayer Varistor
Eaton MLVA02V05C033-R 5.5 V Multilayer Varistor

Eaton MLVA02V05C033-R 5.5 V Multilayer Varistor

Share
MLVA02V05C033-R: multilayer varistor ESD suppressor, 8-14 V varistor voltage, 5.5 V working, 30 V clamp, 33 pF.
    • Product Details
    • Download

    Eaton MLVA02V05C033-R 5.5 V Multilayer Varistor

    MLVA02V05C033-R at a glance: multilayer varistor ESD suppressor, 8-14 V varistor voltage, 5.5 V working, 30 V clamp, 33 pF.

    Specification Table

    ParameterValue
    Orderable part numberMLVA02V05C033-R
    Package size0201
    Working voltage, DC5.5 Vdc
    Varistor voltage at 1 mA8-14 V
    Clamping voltage30 V
    Typical capacitance33 pF
    Package0201 (0603 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 10493

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    A chip varistor is a ceramic body with two metal terminations, so it looks like a capacitor and behaves like one until the transient arrives. That is why the capacitance column is quoted on every page: it is the parameter that decides whether the part can sit on a data line.

    The clamp column works out at 3.75 times the varistor voltage: 30 V at the rated current against 8-14 V at 1 mA. That ratio is what the downstream part has to survive, not the 8-14 V figure on the label.

    The 33 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVA-R family this is item 1 of 10 in the Eaton catalogue.

    Where This Series Fits

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.