MLVA02V05C047-R: multilayer varistor ESD suppressor, 8-14 V varistor voltage, 5.5 V working, 26 V clamp, 47 pF.
    • Product Details
    • Download

    Eaton MLVA02V05C047-R MLV ESD Suppressor 47 pF

    MLVA02V05C047-R at a glance: multilayer varistor ESD suppressor, 8-14 V varistor voltage, 5.5 V working, 26 V clamp, 47 pF.

    Electrical Specifications

    ParameterValue
    Orderable part numberMLVA02V05C047-R
    Package size0201
    Working voltage, DC5.5 Vdc
    Varistor voltage at 1 mA8-14 V
    Clamping voltage26 V
    Typical capacitance47 pF
    Package0201 (0603 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 10493

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 3.25 times the varistor voltage: 26 V at the rated current against 8-14 V at 1 mA. That ratio is what the downstream part has to survive, not the 8-14 V figure on the label.

    The 47 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVA-R family this is item 2 of 10 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • Do not run the part at its varistor voltage: the working voltage column is the continuous limit, and the varistor voltage is 1.5 to 2 times higher only because the ceramic is soft at the knee.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.

    Is the varistor voltage the same as the working voltage?
    No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.