Eaton MLVA06V18C130 0603 Chip Varistor 18 Vdc
Eaton MLVA06V18C130 0603 Chip Varistor 18 Vdc

Eaton MLVA06V18C130 0603 Chip Varistor 18 Vdc

Share
MLVA06V18C130: multilayer varistor ESD suppressor, 17.6-26.4 V varistor voltage, 18 V working, 40 V clamp, 130 pF, 0.1 J.
    • Product Details
    • Download

    Eaton MLVA06V18C130 0603 Chip Varistor 18 Vdc

    MLVA06V18C130 at a glance: multilayer varistor ESD suppressor, 17.6-26.4 V varistor voltage, 18 V working, 40 V clamp, 130 pF, 0.1 J.

    Specification Table

    ParameterValue
    Orderable part numberMLVA06V18C130
    Package size0603
    Working voltage, RMS14 Vrms
    Working voltage, DC18 Vdc
    Varistor voltage at 1 mA17.6-26.4 V
    Clamping voltage40 V
    Typical capacitance130 pF
    Peak current30 A
    Transient energy0.1 J
    Package0603 (1608 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 4070

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 2.27 times the varistor voltage: 40 V at the rated current against 17.6-26.4 V at 1 mA. That ratio is what the downstream part has to survive, not the 17.6-26.4 V figure on the label.

    The 130 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVA family this is item 11 of 12 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.

    Is the varistor voltage the same as the working voltage?
    No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.

    What does the capacitance do to my signal?
    It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.