| Parameter | Value |
|---|---|
| Orderable part number | MLVB06V18C003 |
| Package size | 0603 |
| Working voltage, DC | 18 Vdc |
| Varistor voltage at 1 mA | 22-34 V |
| Clamping voltage | 58 V |
| Typical capacitance | 3 pF |
| Leakage current | max. 10 uA |
| Package | 0603 (1608 metric) |
| Mounting | Surface mount |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 4071 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
A chip varistor is a ceramic body with two metal terminations, so it looks like a capacitor and behaves like one until the transient arrives. That is why the capacitance column is quoted on every page: it is the parameter that decides whether the part can sit on a data line.
The clamp column works out at 2.64 times the varistor voltage: 58 V at the rated current against 22-34 V at 1 mA. That ratio is what the downstream part has to survive, not the 22-34 V figure on the label.
Standing at 18 V the leakage is at most 10 uA, which is 0.18 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.
The 3 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.
Within the MLVB family this is item 7 of 8 in the Eaton catalogue.
The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.
Can it protect a differential pair?
Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.
What happens if the part is run above its working voltage?
Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.
Does the package size change the electrical ratings?
Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd