Eaton MLVC08V016C380 MLV ESD Suppressor 380 pF
Eaton MLVC08V016C380 MLV ESD Suppressor 380 pF

Eaton MLVC08V016C380 MLV ESD Suppressor 380 pF

Share
MLVC08V016C380: multilayer varistor ESD suppressor, 22 V varistor voltage, 16 V working, 39 V clamp, 380 pF, 0.3 J.
    • Product Details
    • Download

    Eaton MLVC08V016C380 MLV ESD Suppressor 380 pF

    MLVC08V016C380 at a glance: multilayer varistor ESD suppressor, 22 V varistor voltage, 16 V working, 39 V clamp, 380 pF, 0.3 J.

    Specification Table

    ParameterValue
    Orderable part numberMLVC08V016C380
    Working voltage, DC16 Vdc
    Working voltage, AC11.3 Vac
    Varistor voltage at 1 mA22 V ±10%
    Clamping voltage at 1 A39 V
    Energy absorption, 10/1000 us0.3 J
    Peak current, 8/20 us120 A
    Typical capacitance at 1 MHz380 pF
    Package0805 (2012 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    A multilayer varistor sits across a signal or supply rail and does nothing until the voltage crosses its breakdown point, at which it turns into a low impedance and diverts the transient. The value that matters for the protected chip is not the varistor voltage but the clamping voltage at the surge current you expect.

    The clamp column works out at 1.77 times the varistor voltage: 39 V at the rated current against 22 V at 1 mA. That ratio is what the downstream part has to survive, not the 22 V figure on the label.

    The 380 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 3 of 97 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • Do not use a varistor as a series element or in a signal path carrying DC. It is a shunt device, and any steady current through it is a fault.
    • These parts are halogen free and RoHS compliant without exemptions, which matters for automotive and appliance programmes.

    Frequently Asked Questions

    What does the capacitance do to my signal?
    It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.