Eaton MLVC12V060C120 60 V Multilayer Varistor
Eaton MLVC12V060C120 60 V Multilayer Varistor

Eaton MLVC12V060C120 60 V Multilayer Varistor

Share
MLVC12V060C120: multilayer varistor ESD suppressor, 76 V varistor voltage, 60 V working, 134 V clamp, 120 pF, 0.1 J.
    • Product Details
    • Download

    Eaton MLVC12V060C120 60 V Multilayer Varistor

    MLVC12V060C120 at a glance: multilayer varistor ESD suppressor, 76 V varistor voltage, 60 V working, 134 V clamp, 120 pF, 0.1 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMLVC12V060C120
    Working voltage, DC60 Vdc
    Working voltage, AC45 Vac
    Varistor voltage at 1 mA76 V ±10%
    Clamping voltage at 1 A134 V
    Energy absorption, 10/1000 us0.1 J
    Peak current, 8/20 us35 A
    Typical capacitance at 1 MHz120 pF
    Package1206 (3216 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11237

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    The Figures Explained

    A multilayer varistor sits across a signal or supply rail and does nothing until the voltage crosses its breakdown point, at which it turns into a low impedance and diverts the transient. The value that matters for the protected chip is not the varistor voltage but the clamping voltage at the surge current you expect.

    The clamp column works out at 1.76 times the varistor voltage: 134 V at the rated current against 76 V at 1 mA. That ratio is what the downstream part has to survive, not the 76 V figure on the label.

    The 120 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC general type family this is item 39 of 41 in the Eaton catalogue.

    What This Family Is For

    Place it on the connector side of any series impedance. A varistor behind a common-mode choke protects the choke and not the connector, which is usually the wrong way round.

    • A varistor is not a zener. It has no sharp knee, so it conducts a little at the working voltage and the leakage column is the honest measure of that.
    • The varistor voltage tolerance is wide by design. Two parts of the same part number can differ by 20 percent and both be good, so the design has to work at the low end of the range.

    Frequently Asked Questions

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products