Eaton MLVC13V018C1200 MLV ESD Suppressor 1200 pF
Eaton MLVC13V018C1200 MLV ESD Suppressor 1200 pF

Eaton MLVC13V018C1200 MLV ESD Suppressor 1200 pF

Share
MLVC13V018C1200: multilayer varistor ESD suppressor, 25 V varistor voltage, 18 V working, 44 V clamp, 1200 pF, 1.5 J.
    • Product Details
    • Download

    Eaton MLVC13V018C1200 MLV ESD Suppressor 1200 pF

    MLVC13V018C1200 at a glance: multilayer varistor ESD suppressor, 25 V varistor voltage, 18 V working, 44 V clamp, 1200 pF, 1.5 J.

    Specification Table

    ParameterValue
    Orderable part numberMLVC13V018C1200
    Working voltage, DC18 Vdc
    Working voltage, AC12.7 Vac
    Varistor voltage at 1 mA25 V ±10%
    Clamping voltage at 1 A44 V
    Energy absorption, 10/1000 us1.5 J
    Peak current, 8/20 us300 A
    Typical capacitance at 1 MHz1200 pF
    Package1210 (3225 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    These parts are zinc oxide ceramics sintered into a chip, so the response is faster than a junction device and there is no wear-out mechanism below the rated energy. What does degrade them is repeated energy above the rating, which shows up as a falling varistor voltage.

    The clamp column works out at 1.76 times the varistor voltage: 44 V at the rated current against 25 V at 1 mA. That ratio is what the downstream part has to survive, not the 25 V figure on the label.

    The 1200 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 27 of 97 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • A varistor is not a zener. It has no sharp knee, so it conducts a little at the working voltage and the leakage column is the honest measure of that.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.