Eaton MLVC13V030C800 MLV ESD Suppressor 800 pF
Eaton MLVC13V030C800 MLV ESD Suppressor 800 pF

Eaton MLVC13V030C800 MLV ESD Suppressor 800 pF

Share
MLVC13V030C800: multilayer varistor ESD suppressor, 42 V varistor voltage, 30 V working, 74 V clamp, 800 pF, 1.5 J.
    • Product Details
    • Download

    Eaton MLVC13V030C800 MLV ESD Suppressor 800 pF

    MLVC13V030C800 at a glance: multilayer varistor ESD suppressor, 42 V varistor voltage, 30 V working, 74 V clamp, 800 pF, 1.5 J.

    Specification Table

    ParameterValue
    Orderable part numberMLVC13V030C800
    Working voltage, DC30 Vdc
    Working voltage, AC21.2 Vac
    Varistor voltage at 1 mA42 V ±10%
    Clamping voltage at 1 A74 V
    Energy absorption, 10/1000 us1.5 J
    Peak current, 8/20 us280 A
    Typical capacitance at 1 MHz800 pF
    Package1210 (3225 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 1.76 times the varistor voltage: 74 V at the rated current against 42 V at 1 mA. That ratio is what the downstream part has to survive, not the 42 V figure on the label.

    The 800 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 31 of 97 in the Eaton catalogue.

    What This Family Is For

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • Do not use a varistor as a series element or in a signal path carrying DC. It is a shunt device, and any steady current through it is a fault.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.