| Parameter | Value |
|---|---|
| Orderable part number | MLVC13V038C650 |
| Working voltage, DC | 38 Vdc |
| Working voltage, AC | 27 Vac |
| Varistor voltage at 1 mA | 51 V ±10% |
| Clamping voltage at 1 A | 90 V |
| Energy absorption, 10/1000 us | 1.5 J |
| Peak current, 8/20 us | 280 A |
| Typical capacitance at 1 MHz | 650 pF |
| Package | 1210 (3225 metric) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11236 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
Multilayer varistors are chosen for board-level ESD and cable-transient protection where a TVS diode would add capacitance. The trade is a softer clamp: the varistor voltage tolerance is wide, so the clamp column, not the nominal voltage, sets the protection level.
The clamp column works out at 1.76 times the varistor voltage: 90 V at the rated current against 51 V at 1 mA. That ratio is what the downstream part has to survive, not the 51 V figure on the label.
The 650 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.
Within the MLVC high energy family this is item 33 of 97 in the Eaton catalogue.
The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.
Can it protect a differential pair?
Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.
What happens if the part is run above its working voltage?
Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.
Does the package size change the electrical ratings?
Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd