Eaton MLVC13V065C400 MLV ESD Suppressor 400 pF
Eaton MLVC13V065C400 MLV ESD Suppressor 400 pF

Eaton MLVC13V065C400 MLV ESD Suppressor 400 pF

Share
MLVC13V065C400: multilayer varistor ESD suppressor, 82 V varistor voltage, 65 V working, 144 V clamp, 400 pF, 1.5 J.
    • Product Details
    • Download

    Eaton MLVC13V065C400 MLV ESD Suppressor 400 pF

    MLVC13V065C400 at a glance: multilayer varistor ESD suppressor, 82 V varistor voltage, 65 V working, 144 V clamp, 400 pF, 1.5 J.

    Electrical Specifications

    ParameterValue
    Orderable part numberMLVC13V065C400
    Working voltage, DC65 Vdc
    Working voltage, AC46 Vac
    Varistor voltage at 1 mA82 V ±10%
    Clamping voltage at 1 A144 V
    Energy absorption, 10/1000 us1.5 J
    Peak current, 8/20 us250 A
    Typical capacitance at 1 MHz400 pF
    Package1210 (3225 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    Multilayer varistors are chosen for board-level ESD and cable-transient protection where a TVS diode would add capacitance. The trade is a softer clamp: the varistor voltage tolerance is wide, so the clamp column, not the nominal voltage, sets the protection level.

    The clamp column works out at 1.76 times the varistor voltage: 144 V at the rated current against 82 V at 1 mA. That ratio is what the downstream part has to survive, not the 82 V figure on the label.

    The 400 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 39 of 97 in the Eaton catalogue.

    Series Positioning

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.