Eaton MLVC18V016C1900 MLV ESD Suppressor 1900 pF
Eaton MLVC18V016C1900 MLV ESD Suppressor 1900 pF

Eaton MLVC18V016C1900 MLV ESD Suppressor 1900 pF

Share
MLVC18V016C1900: multilayer varistor ESD suppressor, 22 V varistor voltage, 16 V working, 39 V clamp, 1900 pF, 2.5 J.
    • Product Details
    • Download

    Eaton MLVC18V016C1900 MLV ESD Suppressor 1900 pF

    MLVC18V016C1900 at a glance: multilayer varistor ESD suppressor, 22 V varistor voltage, 16 V working, 39 V clamp, 1900 pF, 2.5 J.

    Electrical Specifications

    ParameterValue
    Orderable part numberMLVC18V016C1900
    Working voltage, DC16 Vdc
    Working voltage, AC11.3 Vac
    Varistor voltage at 1 mA22 V ±10%
    Clamping voltage at 1 A39 V
    Energy absorption, 10/1000 us2.5 J
    Peak current, 8/20 us500 A
    Typical capacitance at 1 MHz1900 pF
    Package1812 (4532 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 1.77 times the varistor voltage: 39 V at the rated current against 22 V at 1 mA. That ratio is what the downstream part has to survive, not the 22 V figure on the label.

    The 1900 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 43 of 97 in the Eaton catalogue.

    Where This Series Fits

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message