Eaton MLVC18V056C800 Multilayer Varistor, 127 V Clamp
Eaton MLVC18V056C800 Multilayer Varistor, 127 V Clamp

Eaton MLVC18V056C800 Multilayer Varistor, 127 V Clamp

Share
MLVC18V056C800: multilayer varistor ESD suppressor, 72 V varistor voltage, 56 V working, 127 V clamp, 800 pF, 2.5 J.
    • Product Details
    • Download

    Eaton MLVC18V056C800 Multilayer Varistor, 127 V Clamp

    MLVC18V056C800 at a glance: multilayer varistor ESD suppressor, 72 V varistor voltage, 56 V working, 127 V clamp, 800 pF, 2.5 J.

    Specification Table

    ParameterValue
    Orderable part numberMLVC18V056C800
    Working voltage, DC56 Vdc
    Working voltage, AC40 Vac
    Varistor voltage at 1 mA72 V ±10%
    Clamping voltage at 1 A127 V
    Energy absorption, 10/1000 us2.5 J
    Peak current, 8/20 us500 A
    Typical capacitance at 1 MHz800 pF
    Package1812 (4532 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    A multilayer varistor sits across a signal or supply rail and does nothing until the voltage crosses its breakdown point, at which it turns into a low impedance and diverts the transient. The value that matters for the protected chip is not the varistor voltage but the clamping voltage at the surge current you expect.

    The clamp column works out at 1.76 times the varistor voltage: 127 V at the rated current against 72 V at 1 mA. That ratio is what the downstream part has to survive, not the 72 V figure on the label.

    The 800 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 53 of 97 in the Eaton catalogue.

    Where This Series Fits

    Place it on the connector side of any series impedance. A varistor behind a common-mode choke protects the choke and not the connector, which is usually the wrong way round.

    • Do not run the part at its varistor voltage: the working voltage column is the continuous limit, and the varistor voltage is 1.5 to 2 times higher only because the ceramic is soft at the knee.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products