Eaton MLVC22V042C1600 42 V Multilayer Varistor
Eaton MLVC22V042C1600 42 V Multilayer Varistor

Eaton MLVC22V042C1600 42 V Multilayer Varistor

Share
MLVC22V042C1600: multilayer varistor ESD suppressor, 56 V varistor voltage, 42 V working, 99 V clamp, 1600 pF, 2.5 J.
    • Product Details
    • Download

    Eaton MLVC22V042C1600 42 V Multilayer Varistor

    MLVC22V042C1600 at a glance: multilayer varistor ESD suppressor, 56 V varistor voltage, 42 V working, 99 V clamp, 1600 pF, 2.5 J.

    Electrical Specifications

    ParameterValue
    Orderable part numberMLVC22V042C1600
    Working voltage, DC42 Vdc
    Working voltage, AC30 Vac
    Varistor voltage at 1 mA56 V ±10%
    Clamping voltage at 1 A99 V
    Energy absorption, 10/1000 us2.5 J
    Peak current, 8/20 us600 A
    Typical capacitance at 1 MHz1600 pF
    Package2220 (5750 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    A multilayer varistor sits across a signal or supply rail and does nothing until the voltage crosses its breakdown point, at which it turns into a low impedance and diverts the transient. The value that matters for the protected chip is not the varistor voltage but the clamping voltage at the surge current you expect.

    The clamp column works out at 1.77 times the varistor voltage: 99 V at the rated current against 56 V at 1 mA. That ratio is what the downstream part has to survive, not the 56 V figure on the label.

    The 1600 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 62 of 97 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • Do not use a varistor as a series element or in a signal path carrying DC. It is a shunt device, and any steady current through it is a fault.
    • The varistor voltage tolerance is wide by design. Two parts of the same part number can differ by 20 percent and both be good, so the design has to work at the low end of the range.

    Frequently Asked Questions

    Is the varistor voltage the same as the working voltage?
    No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.

    What does the capacitance do to my signal?
    It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.