| Parameter | Value |
|---|---|
| Orderable part number | MLVC32V150C550 |
| Working voltage, DC | 150 Vdc |
| Working voltage, AC | 115 Vac |
| Varistor voltage at 1 mA | 180 V ±10% |
| Clamping voltage at 1 A | 317 V |
| Energy absorption, 10/1000 us | 3.6 J |
| Peak current, 8/20 us | 400 A |
| Typical capacitance at 1 MHz | 550 pF |
| Package | 3225 (8063 metric) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11236 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
A chip varistor is a ceramic body with two metal terminations, so it looks like a capacitor and behaves like one until the transient arrives. That is why the capacitance column is quoted on every page: it is the parameter that decides whether the part can sit on a data line.
The clamp column works out at 1.76 times the varistor voltage: 317 V at the rated current against 180 V at 1 mA. That ratio is what the downstream part has to survive, not the 180 V figure on the label.
The 550 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.
Within the MLVC high energy family this is item 78 of 97 in the Eaton catalogue.
The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.
Can it protect a differential pair?
Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.
What happens if the part is run above its working voltage?
Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.
Does the package size change the electrical ratings?
Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.